Cookie Img Back to top
Send SMS Send Inquiry
+919901301504
          Home » Products » CHAIN & ROPE TESTING MACHINES » CHAIN & ROPE TESTING MACHINES

          CHAIN & ROPE TESTING MACHINES

          CHAIN & ROPE TESTING MACHINES
          CHAIN & ROPE TESTING MACHINES
          Product Code : FCR
          Product Description
          FEATURES: 

          FSA make Horizontal Chain & Rope Testing Machine incorporates following design features.      

          • High loading accuracy
          • Infinitely variable straining speeds to suit a wide range of materials. 
          • Continuous roll autographic recorder to get load elongation graph.
          • Robust loading frame.                                                                                  
          • Simple controls for ease of operation.
          • Adequate safety devices for safe operation.
          •  Analogue models with large dial and digital models with digital display for load and elongation.
          •  Extra features to suit special applications on request.                                                                                                                                                                

          APPLICATION
          Horizontal Chain & Rope Testing Machine are designed to test chain, ropes, and any long specimen for proof test or destructive tensile test.

          TECHNICAL SPECIFICATIONS

          For Analogue Models

          FCR-100kN

          FCR-200kN

          FCR-300kN

          FCR-500kN

          FCR-1000kN

          FCR-2000kN

          FCR-3000kN

          Max. Capacity kN

          100

          200

          300

          500

          1000

          2000

          3000

          1st Measuring Range(kN)X Least count (Kn))

          0-100 X 0.2

          0-200 X 0.4

          0-300 X 0.5

          0-500 X 1

          0-1000 X 2

          0-2000 X 4

          0-3000 X 5

          2nd Measuring Range (kN) X Least count (kN)

          0-50 X 0.1

          0-100 X 0.2

          0-150 X 0.25

          0-250 X 0.5

          0-500 X 1

          0-1000 X 2

          0-1500 X 2.5

          3rd Measuring Range (kN) X Least count (kN)

          0-20 X 0.04

          0-50 X 0.1

          0.60 X 0.1

          0-100 X 0.2

          0-250 X 0.5

          0-500 X 1

          0.600 X 1

          Distance between gripping heads mm (inclusive of Ram stroke)

          100-3000

          100-3000

          100-3000

          100-3000

          100-3000

          100-3000

          100-3000

          Adjusted in steps of mm

          500

          500

          500

          500

          500

          500

          500

          Ram Stroke mm

          500

          500

          500

          500

          600

          600

          600

          Ram Speed (Max.)mm / Min

          300

          200

          150

          120

          60

          60

          35

          Bed Clearance mm

          320

          500

          500

          550

          800

          1000

          1200

          Grips for Round Bar mm

          10-30

          10-30

          10-40

          20-50

          20-60

          20-70

          20-80

          Grips for Wire Rope mm Dia

          10-22

          10-25

          15-35

          15-40

          20-50

          20-60

          20-70

          HP Required

          1.5

          2.5

          2.5

          3

          6

          7

          9.5

          Power Supply

          For Digital Model

          FCRD-100 kN

          FCRD-200 kN

          FCRD-300 kN

          FCRD-500 kN

          FCRD-1000 kN

          FCRD-2000 kN

          FCRD-3000 kN

          Least count for load (kN)

          0.04

          0.1

          0.1

          0.2

          0.5

          1

          1

          Accuracy of +/-1%

          5-100

          10-200

          15-300

          25-500

          50-1000

          100-2000

          150-3000

          in the range kN

          Least count for Elongation mm

          0.1

          0.1

          0.1

          0.1

          0.1

          0.1

          0.1

          All other specifications for Digital models are same as for Analogue Model.


          ROCKWELL TESTING AIDS

          Contact Us

          ( *represents compulsory fields )

          Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.